Skip to content
Solved
SearchBrowse
Sign in

Contents

Official guidance
Construction Industry Scheme Reform Manual

CISR14000 · The Scheme: construction operations

  • CISR14600 · The Scheme: construction operations
  • CISR14010 · Introduction
  • CISR14020 · Scope of CIS
  • CISR14030 · Unusual contracts
  • CISR14040 · Reverse premiums
  • CISR14045 · Reverse premiums – examples of what does and does not constitute a reverse premium for CIS purposes.
  • CISR14047 · Payments made by landlord to tenant payments – Overview
  • CISR14048 · Payments made by landlord to tenant – Regulation 20A
  • CISR14049 · The Scheme: appendix to Regulation 20A
  • CISR14050 · Dealing with 'scope' enquiries
  • CISR14060 · Disputes about 'scope'
  • CISR14070 · Territorial limits
  • CISR14080 · Artistic works
  • CISR14090 · Building service systems
  • CISR14100 · Buildings and structures
  • CISR14110 · Cleaning
  • CISR14120 · Commissioning
  • CISR14130 · Computer and telephone networks
  • CISR14140 · Fencing
  • CISR14150 · Fixed furniture
  • CISR14160 · Fire protection systems
  • CISR14170 · Floor coverings (for example, carpets)
  • CISR14180 · Improvement and housing grants
  • CISR14190 · Industrial plant
  • CISR14200 · Landscaping
  • CISR14210 · Locksmiths
  • CISR14220 · Manufacture and delivery
  • CISR14230 · Mineral extraction
  • CISR14240 · Preparatory, integral and finishing operations
  • CISR14250 · Painting or decorating
  • CISR14260 · Plant hire
  • CISR14270 · Professional work
  • CISR14280 · Seating, blinds and shutters
  • CISR14290 · Security systems
  • CISR14300 · Sign writing and signboards
  • CISR14305 · Traffic management
  • CISR14310 · Electronic communications apparatus
  • CISR14320 · Works forming part of the land
  • CISR14330 · Index of construction operations
  1. The Scheme: construction operations: contents
  2. The Scheme: construction operations: fire protection systems

CISR14160 | The Scheme: construction operations: fire protection systems

From HM Revenue & Customs · Construction Industry Scheme Reform Manual

| CISR14600 | Action guide contents | |—————————————————————————————————–|———————–|

FA04/S74 (2)(c) says that the ‘installation in any building or structure of systems of … fire protection’ is within the scope of the Construction Industry Scheme’.

In practice, systems concerned with the protection of a building and its occupants tend to fall into the following classes

  1. Fire alarm systems providing audible warnings. These are usually triggered by a person.

  2. Fire detection systems made up of a network of heat or smoke sensors that automatically trigger audible/visible warnings.

  3. Fire detection systems made up of a network of heat or smoke sensors that, in addition to triggering audible/visible warnings, set off structural protection systems such as sprinkler systems.

  4. Structural fire protection systems such as sprinkler systems, fireproof cladding and automatic door/Shutter closing mechanisms.

Fire alarm systems and fire detection systems limited to providing audible/visible warnings essentially fulfil a public safety function. In that respect they are technically similar to security warning systems (as in 1 & 2 above). The installation of these systems is considered to be outside the scope of CIS.

Structural fire protection systems and those fire detection systems that interact with structural protection systems fall squarely within the description of ‘systems of fire protection’ (as in 3 & 4 above). The installation of these systems is caught by CIS.