Skip to content
Solved
SearchBrowse
Sign in

Contents

Official guidance
Oils Technical Manual

HCOTEG170000 · Measurement

  • HCOTEG170250 · Scope of guidance
  • HCOTEG170500 · Background
  • HCOTEG171000 · Law and regulations
  • HCOTEG171250 · Notice 179 section 4
  • HCOTEG171500 · Energy Institute (Institute of Petroleum) measurement papers
  • HCOTEG171750 · Measurement Instruments Directive (MID)
  • HCOTEG172500 · What are the responsibilities of the trader/warehouse-keeper?
  • HCOTEG173000 · Health and safety
  • HCOTEG173250 · The importance of the location and the environmental conditions surrounding meters
  • HCOTEG173500 · Security of equipment and contingencies for loss of power
  • HCOTEG173750 · Standard temperature accounting (STA)
  • HCOTEG174000 · Flow meters - technical background
  • HCOTEG174750 · Proving methods - technical background:
  • HCOTEG175250 · Preferred measuring methods
  • HCOTEG175500 · Automatic Level Gauges (ALGs) - technical background
  • HCOTEG175750 · Automatic temperature measurement
  • HCOTEG176000 · Hydrostatic gauges including manometers
  • HCOTEG176250 · Densitometers
  • HCOTEG176500 · Telemetering
  • HCOTEG176750 · Automatic Tank Level Gauges- other factors to consider
  • HCOTEG177250 · Ullaging
  • HCOTEG177500 · Road tank wagon measurement
  • HCOTEG177700 · Tank dipping:
  • HCOTEG177750 · Weighbridges
  • HCOTEG178000 · Vapour recovery
  1. Measurement: contents
  2. Measurement: ullaging

HCOTEG177250 | Measurement: ullaging

From HM Revenue & Customs · Oils Technical Manual

Factors that affect the accuracy of ullage measurements?

Basically, exactly the same things that affect dips, although no ullage could ever take place on a floating roof.

Requirements for Ullaging

The needs of tank dipping (See HCOTEG177700) mostly apply here. Ullaging could be used in Rail Tank Wagons where there is no automatic loading meter. This is rare.

The difference in our requirements for ‘ullaging’ are:

  1. The tank must be constructed so that the height from the top of the liquid to the ullaging point (marked at the top of the tank) can be converted to the volume of liquid within the tank, by using a calibration table compiled specifically for each tank, i.e. the tank must be designed and built specifically in order to allow ullaging.

  2. The ullaging rod should be graduated in 2mm gradations.

  3. The must be an absence of water where it is the total volume of oil which matters (as opposed to measuring the ‘opening’ and ‘closing’ volumes).