Skip to content
Solved
SearchBrowse
Sign in

Contents

Official guidance
Oils Technical Manual

HCOTEG170000 · Measurement

  • HCOTEG170250 · Scope of guidance
  • HCOTEG170500 · Background
  • HCOTEG171000 · Law and regulations
  • HCOTEG171250 · Notice 179 section 4
  • HCOTEG171500 · Energy Institute (Institute of Petroleum) measurement papers
  • HCOTEG171750 · Measurement Instruments Directive (MID)
  • HCOTEG172500 · What are the responsibilities of the trader/warehouse-keeper?
  • HCOTEG173000 · Health and safety
  • HCOTEG173250 · The importance of the location and the environmental conditions surrounding meters
  • HCOTEG173500 · Security of equipment and contingencies for loss of power
  • HCOTEG173750 · Standard temperature accounting (STA)
  • HCOTEG174000 · Flow meters - technical background
  • HCOTEG174750 · Proving methods - technical background:
  • HCOTEG175250 · Preferred measuring methods
  • HCOTEG175500 · Automatic Level Gauges (ALGs) - technical background
  • HCOTEG175750 · Automatic temperature measurement
  • HCOTEG176000 · Hydrostatic gauges including manometers
  • HCOTEG176250 · Densitometers
  • HCOTEG176500 · Telemetering
  • HCOTEG176750 · Automatic Tank Level Gauges- other factors to consider
  • HCOTEG177250 · Ullaging
  • HCOTEG177500 · Road tank wagon measurement
  • HCOTEG177700 · Tank dipping:
  • HCOTEG177750 · Weighbridges
  • HCOTEG178000 · Vapour recovery
  1. Measurement: contents
  2. Measurement: weighbridges

HCOTEG177750 | Measurement: weighbridges

From HM Revenue & Customs · Oils Technical Manual

Introduction

The MID has a section dedicated to Rail Weighbridges: The Measuring Instruments (Automatic Rail-weighbridges) Regulations 2006. However, there is no such section for road weighbridges.

Requirements for weighbridges

Public road vehicle weighbridges

There are legal requirements for public weighbridges that do not apply to private ones. After checking on installation, the Trading Standards Officer (TSO) will check (reprove) the weighbridge every six months and give it a stamp. This stamp will be obliterated by the TSO if it fails a test, but will be reinstated if it passes. Any weighbridge certified by the TSO is acceptable to us.

Private road vehicle weighbridges

As above, the TSO will stamp the weighbridge on installation. However, from then on it is up to the trade to have the weighbridge re-proved - the TSO will not test the weighbridge as a matter of course and obliterate the stamp if it is found inaccurate. The weighbridge is only acceptable therefore if it has been reproved at least annually.

Rail weighbridges

Top of page

Accuracy classes of weighbridges

As with flow meters, there will be accuracy classes of weighbridge, and these are:

Accuracy ClassMaximum permissible error expressed as a percentage of mass of a single wagon or total train as appropriate
0.2+ or - 0.2%
0.5+ or - 0.5%
1+ or - 1%
2+ or - 2%
PreviousNext